Mill-certified reinforcing steel — BS 4449 · ASTM A615 · ISO 6935sales@steelrebargermany.deWhatsApp +49 163 1141934
Welded wire mesh reinforcement panels for concrete

Q524 Reinforcing Mesh — 10 mm Wire, 5.24 cm²/m Welded Fabric | Steel Rebar Germany

Welded Fabric · DIN 488-4 · EN 10080

Q524 Reinforcing Steel Mesh

Square (Q-type) welded fabric with 10 mm wires at 150 mm pitch — providing approximately 5.24 cm²/m cross-section in both directions. Manufactured to DIN 488-4 and EN 10080, Q524 is the heaviest standard 150 mm pitch square mesh, suited to heavily reinforced flat plates, deep transfer slabs, and infrastructure applications requiring a high base reinforcement area before supplementary bars are added.

DIN 488-4 · EN 10080 Mill Test Certificate EN 10204 3.1 Export worldwide

Q524 Mesh: Technical Specification

Q524 is the uppermost standard square (Q) mesh grade at 150 mm wire pitch in the DIN 488-4 range. The designation “524” encodes the nominal cross-sectional area per metre: 5.24 cm²/m (524 mm²/m). Both longitudinal and transverse wires are 10.0 mm in diameter at 150 mm pitch.

Using the standard reinforcing steel weight formula (kg/m = d² × 0.00617), a single 10 mm wire weighs 0.617 kg/m. Q524 thus has an approximate sheet weight of 9.27 kg/m² — the heaviest in the standard 150 mm pitch Q-family. The 10 mm wire cross-section (78.5 mm² per wire) is directly readable from standard reinforcing steel section tables and integrates naturally into Eurocode 2 design calculations.

Standard panel size is 6.0 × 2.3 m. Grade is B500A or B500B to EN 10080. All intersections are joined by electrical resistance welding to the shear-bond requirements of DIN 488-4.

Dimensional and Weight Summary

ParameterValue
Wire diameter (longitudinal & transverse)10.0 mm (nominal)
Wire pitch (both directions)150 mm
Cross-section per metre (As)≈ 5.24 cm²/m (524 mm²/m)
Single wire cross-section78.5 mm² (π/4 × 10²)
Approx. sheet weight≈ 9.27 kg/m²
Standard sheet size6.0 × 2.3 m (13.8 m²/sheet)
Steel gradeB500A / B500B to EN 10080
StandardDIN 488-4, EN 10080
Weld typeElectrical resistance welding

Applications for Q524 Welded Mesh

Where the maximum standard-pitch square mesh delivers structural and programme advantages.

🏗️

Heavy Transfer Slabs

Deep transfer plates (350–500 mm) carrying shear wall or column loads from upper floors require high base reinforcement. Q524 provides the highest standard As at 150 mm pitch before moving to closer-spaced or bespoke grids.

🏢

Flat-Plate High-Rise Floors

In punching-shear critical flat-plate designs for residential towers, Q524 as the distributed field mesh reduces the number of additional loose bar layers needed in non-critical zones, simplifying reinforcement scheduling.

High-Rise →
🌉

Bridge Decks

Bridge deck slabs exposed to traffic and de-icing salts need robust crack-width control per Eurocode 2 and EN 1992-2. Q524 B500B provides the cross-section and ductility often required by bridge deck reinforcement schedules as the continuous slab mesh.

Infrastructure →
🏭

Heavy Industrial Floors

Port aprons, heavy vehicle maintenance bays, and primary processing plant floors with very high wheel loads (50+ tonnes) frequently specify Q524 as the base mesh to control reflective cracking through the full slab depth.

Foundations →
📦

Precast Structural Elements

Heavily loaded precast beams and columns use Q524 as a peripheral cage element in combination with main longitudinal bars; the mesh maintains bar spacing and provides confinement contribution in compression zones.

Precast →
🧱

Raft Foundations

Mat foundations for multi-storey structures with heavy column loads benefit from Q524 as the continuous lower mat reinforcement, replacing loose bar grids and reducing fixing time on site.

Foundations →

Standards, Grade, and Export Documentation

Q524 is manufactured to DIN 488-4 and the European harmonised standard EN 10080. Wire grade is B500A or B500B — 500 MPa minimum characteristic yield strength (fyk). B500B (k ≥ 1.08, Agt ≥ 5.0%) is the preferred grade for structural applications requiring Eurocode 2 ductility class B; B500A (k ≥ 1.05, Agt ≥ 2.5%) is adequate where normal ductility suffices.

The 10 mm wire — cross-section 78.5 mm², weight 0.617 kg/m — is one of the tabulated standard wire sizes in DIN 488-4, ensuring straightforward traceability between the product data sheet and the structural engineer’s reinforcement schedule. Every shipment from Steel Rebar Germany includes:

  • EN 10204 Type 3.1 Mill Test Certificate — chemical composition, Re, Rm, Agt, dimensional checks, heat traceable
  • CE Declaration of Performance per EN 10080 / Annex ZA
  • Certificate of Origin (chamber-stamped or notarised)
  • Packing list: bundle dimensions, sheet counts, gross / net weights, container load plan
  • Seaworthy packaging — wire-bound bundles, moisture-inhibiting wrapping for FCL or break-bulk freight
Standards & Certification → Export & Delivery →

Q-Type Mesh Comparison

Q524 in context — the heaviest 150 mm pitch square mesh in the DIN 488-4 standard range.

GradeWire Dia (mm)Pitch (mm)As (cm²/m)Approx. Weight (kg/m²)
Q2577.01502.57≈ 4.50
Q3358.01503.35≈ 5.93
Q4249.01504.24≈ 7.51
Q524 (this page)10.01505.24≈ 9.27
Q6369.01006.36≈ 11.25

All grades to DIN 488-4 / EN 10080. Full mesh sizes guide → | Mesh overview →

Frequently Asked Questions — Q524 Mesh

What is the difference between Q524 and Q636, and when should I choose Q524?
Q524 uses 10 mm wires at 150 mm pitch (As = 5.24 cm²/m); Q636 uses 9 mm wires at 100 mm pitch (As = 6.36 cm²/m). Q524 is lighter per m² (9.27 vs ~11.25 kg/m²) and has a wider pitch, which can simplify concrete workability and aggregate compaction in heavily reinforced zones. Choose Q524 when the design requires more than Q424 but the structural engineer’s As requirement does not justify moving to the 100 mm pitch of Q636. For crack-width control governed by bar spacing limits in EC2 Table 7.2, the closer 100 mm pitch of Q636 may be required — verify with the structural engineer.
Is Q524 available in B500B for seismic applications?
Yes. Q524 B500B (high ductility, k ≥ 1.08, Agt ≥ 5.0%) is available and can be specified in seismic design situations governed by Eurocode 8 (EN 1998) where ductility class B reinforcement is permitted. For DCH structures, check whether grade B500C (1.15 ≤ k < 1.35, Agt ≥ 7.5%) is required by the national annex or the project specification.
How do I calculate the number of Q524 sheets for a project?
Calculate the plan area of mesh required (m²), add 20–30% for overlaps (typically 150–300 mm per edge), then divide by the single sheet area of 13.8 m² (6.0 × 2.3 m). To get tonnage, multiply total m² by 9.27 kg/m² and divide by 1000. Provide us with the net area, overlap allowance, and any cutting requirements when requesting a quote — we will confirm the exact sheet count and freight weight.
Can Q524 be supplied in non-standard sheet sizes?
Yes. Custom sheet dimensions can be cut to your reinforcement schedule, subject to minimum order quantities. Longer sheets (e.g. 7.2 m or 9.0 m) may be available to reduce laps in long-span slabs. Advise your requirements on the quote form and we will confirm feasibility and lead time.
What documentation is required for importing Q524 mesh into non-EU markets?
Requirements vary by destination country. At minimum, most markets require the EN 10204 Type 3.1 Mill Test Certificate and a Certificate of Origin. Some jurisdictions additionally require a CE Declaration of Performance, a phytosanitary inspection of packing materials, or a specific customs tariff classification. We prepare a complete export documentation package and can advise on destination-specific requirements — please mention your destination port when requesting a quote.

Source German-standard rebar with full export documentation

Tell us your Q524 mesh specification and destination port — we’ll respond with a detailed quotation.

Request a Quote →